TPC116S4-TR

3PEAK TPC116S4-TR

Part No:

TPC116S4-TR

Manufacturer:

3PEAK

Package:

16-TSSOP (0.173", 4.40mm Width)

AINNX NO:

68735670-TPC116S4-TR

Description:

16 BIT DIGITAL TO ANALOG CONVERT

Products specifications
  • Package / Case
    16-TSSOP (0.173", 4.40mm Width)
  • Mounting Type
    Surface Mount
  • Supplier Device Package
    16-TSSOP
  • Series
    TPC116S4
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 125°C
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Output Type
    Voltage - Buffered
  • Number of Bits
    16
  • Architecture
    String DAC
  • Reference Type

    a code object that is not stored directly where it is created, but that acts as a kind of pointer to a value stored elsewhere.

    External
  • Data Interface

    A Data Interface in EDQ is a template of a set of attributes representing a given entity, used to create processes that read from, or write to, interfaces rather than directly from or to sources or targets of data.

    Microwire, QSPI, Serial, SPI
  • Differential Output

    a differential output voltage in electronics is the difference between the values of two AC voltages, 180° out of phase, present at the output terminals of an amplifier when you apply a differential input voltage to the input terminals of an amplifier.

    No
  • Voltage - Supply, Analog
    2.7V ~ 5.5V
  • Voltage - Supply, Digital
    2.7V ~ 5.5V
  • Settling Time

    In control theory the settling time of a dynamical system such as an amplifier or other output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band.

    14µs
  • INL/DNL (LSB)
    ±8, ±0.5
  • Number of D/A Converters
    1
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for 3PEAK TPC116S4-TR.