AZ943-1CH-12DE

American Zettler AZ943-1CH-12DE

Part No:

AZ943-1CH-12DE

Manufacturer:

American Zettler

Package:

300

ROHS:

AINNX NO:

21319946-AZ943-1CH-12DE

Description:

Power Relay 12VDC 10A SPDT(19.25x15.49x15.95)mm THT

Products specifications
  • Package / Case
    300
  • Mount
    PCB, Through Hole
  • Mounting Type
    Through Hole
  • Surface Mount

    having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.

    NO
  • Mounting Feature

    a process by which the operating system makes files and directories on a storage device (such as hard drive, CD-ROM, or network share) available for users to access via the computer's file system.

    THROUGH HOLE-STRAIGHT MOUNT
  • Number of Pins
    5
  • Weight
    10 g
  • Number of Terminals
    5
  • End Contact Material
    Silver Tin Oxide
  • Manufacturer Package Identifier
    AZ943-1CH-12DE
  • CoilResistance
    400 Ω
  • Contact Materials
    Silver, Tin
  • Voltage Rating (AC)
    300 V
  • RoHS
    Compliant
  • Approvals
    TUV, UL
  • Package
    Tube
  • Base Product Number
    AZ943
  • Mfr
    American Zettler
  • Product Status
    Active
  • Coil Voltage-Nom
    12 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    90 °C
  • Rohs Code
    Yes
  • Manufacturer Part Number
    AZ943-1CH-12DE
  • Manufacturer
    American ZETTLER Inc
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    AMERICAN ZETTLER INC
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    1.64
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 90°C
  • Series
    -
  • JESD-609 Code
    e3
  • Termination
    PC Pin
  • ECCN Code
    EAR99
  • Terminal Finish
    Tin (Sn)
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    70 °C
  • Min Operating Temperature
    -40 °C
  • Reach Compliance Code
    compliant
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    15 A
  • Reference Standard
    CUR; TUV; UL
  • Termination Style
    PC Pin
  • Approval Agency
    TUV, UL
  • Body Length or Diameter
    19.25 mm
  • Number of Contacts
    1
  • Body Breadth
    15.49 mm
  • Physical Dimension
    19.25mm x 15.49mm x 15.95mm
  • Contact Resistance
    100 mΩ
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    100000000 Ω
  • Contact Current(DC)-Max
    10 A
  • Sealing
    EPOXY
  • Contact Voltage(DC)-Max
    30 V
  • Max Voltage Rating (AC)
    300 V
  • Termination Type
    SOLDER
  • Max Current Rating
    15 A
  • Throw Configuration
    SPDT
  • Max Voltage Rating (DC)
    30 V
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    General Purpose
  • Contact Current(AC)-Max
    10 A
  • Contact (AC) Max Rating R Load
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    10 ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non-Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    277VAC, 30VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    30 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5 ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    9 VDC
  • Contact Rating (Current)
    10 A
  • Coil Power
    203 mW
  • Must Release Voltage
    1.2 VDC
  • Contact Voltage(AC)-Max
    277 V
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    12 V
  • Coil/Input Supply Type
    DC
  • PCB Hole Count
    5
  • Seal Rating
    Sealed - Fully
  • Dielectric Strength Between Open Contacts
    750 Vrms
  • Input Switching Control Type
    Random
  • Coil Insulation
    Class B
  • Dielectric Strength Between Coil and Contacts
    1500 Vrms
  • Ambient Temperature Range High

    This varies from person to person, but it is somewhere between 68 and 77 degrees F on average. The temperature setting that is comfortable for an individual may fluctuate with humidity and outside temperature as well. The temperature of an air conditioned room can also be considered ambient temperature.

    70 °C
  • Contact (AC) Max Power Rating R Load
  • Switching Current
    10 A
  • Contact (DC) Max Power Rating R Load
  • Relay Function
    SPDT
  • Coil Voltage(DC)-Max
    15.6 V
  • Relay Form
    1 FORM C
  • Coil Operate Voltage(DC)
    9 V
  • Features
    -
  • Terminal Length
    0.0035 inch
  • Height
    15.7 mm
  • Length
    19 mm
  • Width
    15.3 mm
  • Body Height
    15.95 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining