AZ9571-1C-24DSE

American Zettler AZ9571-1C-24DSE

Part No:

AZ9571-1C-24DSE

Manufacturer:

American Zettler

Datasheet:

-

Package:

DIP

AINNX NO:

28497032-AZ9571-1C-24DSE

Description:

RELAY SIGNAL SPDT 1A 24VDC PCB

Products specifications
  • Mounting Type
    Through Hole
  • Package / Case
    DIP
  • Mount
    Through Hole
  • Number of Pins
    6
  • Weight
    2.2 g
  • Number of Terminals
    6
  • End Contact Material
    Silver
  • End Contact Plating
    GOLD
  • Mfr
    American Zettler
  • Package
    Tray
  • Product Status
    Active
  • Contact Materials
    Silver (Ag), Gold (Au)
  • CoilResistance
    3.84 kOhms
  • Rad Hardened
    No
  • Maximum Power Rating
    30W/62.5VA
  • Seal
    Sealed
  • Dropout Volt
    >2.4VDC
  • Voltage Rating (VDC)
    60(V)
  • Mounting Styles
    Through Hole
  • Operating Temp Range
    -40C to 70C
  • LED Indicator
    No
  • Product Depth (mm)
    7.8(mm)
  • Pick-up Voltage (Max)
    19.2VDC
  • Relay Construction
    Non-Latching
  • RoHS
    Non-Compliant
  • Coil Voltage-Nom
    24 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    70 °C
  • Rohs Code
    Yes
  • Manufacturer Part Number
    AZ9571-1C-24DSE
  • Manufacturer
    American ZETTLER Inc
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    AMERICAN ZETTLER INC
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    5.65
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 70°C
  • JESD-609 Code
    e3
  • Termination
    PC Pin
  • Terminal Finish
    Tin
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    70 °C
  • Min Operating Temperature
    -40 °C
  • Reach Compliance Code
    compliant
  • Pin Count

    a count of all of the component leads (or pins)

    6
  • Reference Standard
    UL
  • Termination Style
    PC Pin
  • Body Length or Diameter
    12.8 mm
  • Body Breadth
    7.8 mm
  • Physical Dimension
    12.8mm x 7.8mm x 10.8mm
  • Contact Resistance
    100 mΩ
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    100000000 Ω
  • Contact Current(DC)-Max
    1 A
  • Sealing
    EPOXY
  • Contact Voltage(DC)-Max
    60 V
  • Max Voltage Rating (AC)
    125 V
  • Termination Type
    SOLDER
  • Max Current Rating
    1 A
  • Throw Configuration
    SPDT
  • Max Voltage Rating (DC)
    60 V
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    1(A)
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    General Purpose
  • Contact Current(AC)-Max
    1 A
  • Contact (AC) Max Rating R Load
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    5 ms
  • Coil Voltage
    24VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    125VAC, 60VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    6.3 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5 ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    19.2 VDC
  • Contact Rating (Current)
    1 A
  • Must Release Voltage
    2.4 VDC
  • Contact Voltage(AC)-Max
    125 V
  • Contact/Output Supply Type
    AC/DC
  • Coil Voltage (DC)
    24
  • Coil/Input Supply Type
    DC
  • PCB Hole Count
    6
  • Seal Rating
    Sealed - Fully
  • Dielectric Strength Between Open Contacts
    400 Vrms
  • Input Switching Control Type
    Random
  • Coil Insulation
    -
  • Dielectric Strength Between Coil and Contacts
    1000 Vrms
  • Contact (AC) Max Power Rating R Load
  • Contact (DC) Max Power Rating R Load
  • Relay Function
    SPDT
  • Contact Arrangement
    SPDT
  • Coil Voltage(DC)-Max
    48 V
  • Relay Form
    1 FORM C
  • Coil Operate Voltage(DC)
    19.2 V
  • Features
    -
  • Terminal Length
    0.0035 inch
  • Coil Suppression Diode

    A coil spike suppression diode is a protection device across the contactor coil. Energizing the contactor coil creates a magnetic field that forces the solenoid arm to engage the contacts. When the contactor is turned off, the magnetic field collapses causing a back “voltage spike” that can damage the controller.

    No
  • Voltage Rating (VAC)
    125(V)
  • Product Length (mm)
    12.8(mm)
  • Width
    7.8 mm
  • Height
    10.3 mm
  • Length
    12.8 mm
  • Body Height
    10.8 mm
  • Product Height (mm)
    10.3(mm)
0 Similar Products Remaining