OCC3DC3BT-150.000M-TR

Ascend OCC3DC3BT-150.000M-TR

Part No:

OCC3DC3BT-150.000M-TR

Manufacturer:

Ascend

Datasheet:

-

Package:

6-SMD, No Lead

AINNX NO:

35497636-OCC3DC3BT-150.000M-TR

Category:

Oscillators

Description:

XTAL OSC XO 150.0000MHZ 6PAD PKG

Products specifications
  • Mounting Type
    Footed
  • Package / Case
    6-SMD, No Lead
  • Enclosure
    Totally Enclosed Fan Cooled
  • Manufacturer Part Number
    0032SDJC41P-P
  • Manufacturer
    Toshiba
  • RoHS
    No
  • Package
    Bulk
  • Mfr
    Ascend Frequency Devices
  • Product Status
    Active
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 85°C
  • Series
    OCC3D
  • Size / Dimension
    0.283 L x 0.205 W (7.20mm x 5.20mm)
  • Type
    Definite Purpose
  • Composition
    Cast Iron
  • Voltage - Supply
    3.3V
  • Frequency
    60 Hz
  • Frequency Stability

    the variation of output frequency of a crystal oscillator due to external conditions like temperature variation, voltage variation, output load variation, and frequency aging.

    ±25ppm
  • Output
    LVDS
  • Function
    Enable/Disable
  • Base Resonator
    Crystal
  • Current - Supply (Max)
    50mA
  • Current - Supply (Disable) (Max)
    -
  • Spread Spectrum Bandwidth

    In telecommunication and radio communication, spread-spectrum techniques are methods by which a signal (e.g., an electrical, electromagnetic, or acoustic signal) generated with a particular bandwidth is deliberately spread in the frequency domain, resulting in a signal with a wider bandwidth.

    -
  • RPM
    3,600 RPM
  • Bearing Type

    there are several different types of bearings, including ball and roller bearings, linear bearings, as well as mounted versions that may use either rolling element bearings or plain bearings.

    Ball
  • Absolute Pull Range (APR)
    -
  • Overload Protection

    Overload protection is a protection against a running overcurrent that would cause overheating of the protected equipment. Hence, an overload is also type of overcurrent. Overload protection typically operates on an inverse time curve where the tripping time becomes less as the current increases.

    None
  • Phase
    3
  • Height Seated (Max)
    0.079 (2.00mm)
  • Ratings
    -
0 Similar Products Remaining