BOS01L8

Balluff BOS01L8

Part No:

BOS01L8

Manufacturer:

Balluff

Datasheet:

-

Package:

-

AINNX NO:

28235421-BOS01L8

Description:

SERIES=6K, DIMENSION=12 X 41.5 X

Products specifications
  • Housing Material
    ABS
  • Mfr
    Balluff
  • Package
    Bag
  • Product Status
    Active
  • RoHS
    Compliant
  • Type of electric connection
    Plug-in connection
  • Voltage type
    DC
  • Degree of protection (IP)
    IP67
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +60°C
  • Minimum Operating Temperature
    -20°C
  • Switching Mode
    Light / Dark switching
  • Series
    6K
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C ~ 60°C
  • Voltage - Supply
    10V ~ 30V
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP67, IP69K
  • Output Type
    PNP
  • Output Configuration
    PNP-NC/NO
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    -
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    -
  • Adjustment Type
    Adjustable
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    78.740" (2m)
  • Sensing Method
    Retroreflective
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Connector, M8
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    Red (660nm)
  • Electrical Connection
    M8 4 Pin Connector
  • IP Rating

    IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.

    IP67/IP69K
0 Similar Products Remaining