1530-1D

Bourns Inc. 1530-1D

Part No:

1530-1D

Manufacturer:

Bourns Inc.

Package:

-

AINNX NO:

7805817-1530-1D

Description:

Surge Suppressor; Ethernet; 10kA; 60V; DIN Rail Mount; RJ45; IP20; 35W; 1530-1 Series

Products specifications
  • Factory Lead Time
    8 Weeks
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Terminal Shape
    FLAT
  • Housing Material
    Plastic
  • Number of Elements
    1
  • Operating Temperature (Max.)
    125°C
  • Operating Temperature (Min.)
    -55°C
  • Series
    1530-1
  • Published
    2015
  • Tolerance
    0.5%
  • JESD-609 Code
    e3
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    8
  • Termination
    Lug
  • ECCN Code
    EAR99
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    25 ppm/°C
  • Type
    Surge Protection Module
  • Terminal Finish
    Tin (Sn)
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8533.21.00.10
  • Voltage - Rated DC
    57V
  • Number of Functions
    4
  • Reach Compliance Code
    not_compliant
  • Rated Power Dissipation (P)
    1.09W
  • Approval Agency
    CSA, IEC, IEEE, UL
  • Working Voltage
    50V
  • Rated Temperature
    70°C
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    1A
  • Turn On Delay Time

    Turn-on delay, td(on), is the time taken to charge the input capacitance of the device before drain current conduction can start.

    1 μs
  • Element Power Dissipation
    0.2W
  • First Element Resistance
    5300Ohm
  • Overload Protection

    Overload protection is a protection against a running overcurrent that would cause overheating of the protected equipment. Hence, an overload is also type of overcurrent. Overload protection typically operates on an inverse time curve where the tripping time becomes less as the current increases.

    Fuse Holder
  • AC Outlets
    None
  • Temperature Coefficient Tracking
    5 ppm/°C
  • Length
    65.1mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    Non-RoHS Compliant
  • Ratings
    IP20
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Bourns Inc. 1530-1D.