VAA1005

Cosel USA, Inc. VAA1005

Part No:

VAA1005

Manufacturer:

Cosel USA, Inc.

Package:

5-DIP Module

ROHS:

AINNX NO:

3674216-VAA1005

Description:

Power Supply;AC-DC;5V;2A;85-132V In;Open Frame;Thru-Hole;Embedded;10W;VAA Series

Products specifications
  • Factory Lead Time
    6 Weeks
  • Mount
    PCB, Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    5-DIP Module
  • Weight
    35g
  • Usage Level
    Commercial grade
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -10°C~70°C With Derating
  • Series
    VAA (10W)
  • Published
    2001
  • Size / Dimension
    2.85Lx1.26W x 0.71 H 72.4mmx32.0mmx18.0mm
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Number of Terminations
    5
  • Type
    Open Frame
  • Applications
    ITE (Commercial)
  • Power Rating
    10W
  • Terminal Position
    UNSPECIFIED
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    PIN/PEG
  • Number of Functions
    1
  • Depth
    18mm
  • Reach Compliance Code
    unknown
  • JESD-30 Code
    R-XXMA-P5
  • Number of Outputs
    1
  • Approval Agency
    cURus
  • Efficiency
    76%
  • Output Voltage
    5V
  • Input Voltage-Nom
    100V
  • Trim/Adjustable Output
    NO
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    2A
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    10W
  • Current - Output 1
    2A
  • Input Current
    300mA
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    3kV
  • Line Regulation

    Line regulation is the ability of a power supply to maintain a constant output voltage despite changes to the input voltage, with the output current drawn from the power supply remaining constant.

    20mV
  • Load Regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

    40mV
  • Height
    18mm
  • Length
    72.5mm
  • Width
    32mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Cosel USA, Inc. VAA1005.