88886116

Crouzet 88886116

Part No:

88886116

Manufacturer:

Crouzet

Package:

-

ROHS:

AINNX NO:

5351758-88886116

Description:

RELAY TIME DELAY 300HRS 5A 250V

Products specifications
  • Factory Lead Time
    4 Weeks
  • Mount
    Plug-In, Socket
  • Mounting Type
    Socketable
  • Number of Pins
    8
  • Weight
    140g
  • Coil Voltage AC
    230V
  • Series
    TMR 48
  • Published
    2003
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Plug
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    55°C
  • Min Operating Temperature
    -20°C
  • Power Rating
    2kW
  • Voltage - Supply
    24V~240VAC 12V~240VDC
  • Depth
    80mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    5A
  • Termination Style
    Plug In, 8 Pin (Octal)
  • Function
    Programmable (Multi-Function)
  • Voltage - Rated AC
    250V
  • Number of Contacts
    2
  • Circuit
    DPDT (2 Form C)
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    240V
  • Max Current Rating
    5A
  • Number of Poles
    2
  • Throw Configuration
    DPDT
  • Accuracy
    0.5 %
  • Relay Type
    Mechanical Relay
  • Nominal Input Voltage

    The actual voltage at which a circuit operates can vary from the nominal voltage within a range that permits satisfactory operation of equipment. The word “nominal” means “named”.

    240V
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    4.8W
  • Contact Rating @ Voltage
    5A @ 250VAC
  • Coil Voltage (DC)
    24V
  • Max Supply Voltage (DC)
    240V
  • Min Supply Voltage (DC)
    12V
  • Max Supply Voltage (AC)
    240V
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.02 Sec ~ 300 Hrs
  • Timing Adjustment Method
    Hand Dial
  • Timing Initiate Method

    The initiation time (also known as release time) is the time at which the process goes from the waiting to the ready state. An aperiodic process is by definition initiated by an event, such as external data arriving or data computed by another process.

    Input Voltage
  • Min Supply Voltage (AC)
    24V
  • Length
    48mm
  • Width
    48mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining