38.61.7.024.4050

Finder Relays, Inc. 38.61.7.024.4050

Part No:

38.61.7.024.4050

Manufacturer:

Finder Relays, Inc.

Datasheet:

-

Package:

-

AINNX NO:

28496422-38.61.7.024.4050

Description:

RELAY GEN PURPOSE SPDT 6A 24V

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Finder Relays, Inc.
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    Silver Tin Oxide (AgSnO)
  • Dim
    (L x W x H) 93.6 x 6.2 x 76 mm
  • Connections
    Pull spring
  • Content
    1pc(s)
  • Electrical lifespan
    (AC1) 60 x 10<sup>3</sup> switching cycles
  • Nominal current
    6
  • Type of electric connection
    Spring clamp connection
  • Number of contacts as change-over contact
    1
  • Number of contacts as normally open contact
    0
  • Degree of protection (IP)
    IP20
  • Voltage type for actuating
    DC
  • Number of contacts as normally closed contact
    0
  • Rated control supply voltage at DC
    24 - 24
  • With detachable clamps
    No
  • Series
    38
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 55°C
  • Type
    38.61.7.024.4050
  • Depth
    93
  • Termination Style
    Spring Terminal
  • Durability
    10 x 10<sup>6</sup> switching cycles
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    5 ms
  • Coil Voltage
    24VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    400VAC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    10.4 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    6 ms
  • Must Operate Voltage
    19.2 VDC
  • Contact Rating (Current)
    6 A
  • Must Release Voltage
    1.2 VDC
  • Seal Rating
    -
  • Coil Insulation
    -
  • Features
    Socket Included
  • Width
    6.2mm
  • Height
    76mm
  • Length
    93.6mm