103SR17A-1

Honeywell Sensing and Productivity Solutions 103SR17A-1

Part No:

103SR17A-1

Package:

Cylinder, Threaded

ROHS:

AINNX NO:

7544959-103SR17A-1

Description:

Hall Effect Sensor 20mA Bipolar 5V/9V/12V/15V/18V 3-Pin

Products specifications
  • Factory Lead Time
    25 Weeks
  • Mount
    Panel
  • Package / Case
    Cylinder, Threaded
  • Number of Pins
    3
  • Actuator Material

    In smart material system, actuator materials have the ability to change the shape, stiffness, position, natural frequency, damping and/or other mechanical characteristics of the smart material systems in response to changes in temperature, electric field and/or magnetic field.

    Magnet
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~100°C TA
  • Series
    103SR
  • Published
    1998
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Wire Leads
  • Type
    Hall Effect Switch
  • Voltage - Supply
    4.5V~24V
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    UNSPECIFIED
  • Peak Reflow Temperature (Cel)
    NOT SPECIFIED
  • Number of Functions
    1
  • Reach Compliance Code
    unknown
  • Time@Peak Reflow Temperature-Max (s)
    NOT SPECIFIED
  • Termination Style
    Wire Leads
  • JESD-30 Code
    X-XXSS-X
  • Qualification Status

    An indicator of formal certification of qualifications.

    Not Qualified
  • Output Type
    Digital, Open Collector
  • Max Output Current

    The maximum current that can be supplied to the load.

    20mA
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    12V
  • Supply Voltage-Max (Vsup)
    24V
  • Supply Voltage-Min (Vsup)
    4.5V
  • Leakage Current
    20μA
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    10mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    20mA
  • Must Operate
    20.5mT
  • Must Release
    -20.5mT
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Honeywell Sensing and Productivity Solutions 103SR17A-1.