HEL-705-U-0-12-00

Honeywell Sensing and Productivity Solutions HEL-705-U-0-12-00

Part No:

HEL-705-U-0-12-00

Package:

Cylindrical Probe, Plastic

ROHS:

AINNX NO:

7739944-HEL-705-U-0-12-00

Description:

HONEYWELL HEL-705-U-0-12-00 RTD Sensor, Platinum, 1 kohm, -200 C, +260 C, HEL-700 Series

Products specifications
  • Factory Lead Time
    10 Weeks
  • Mount
    Through Hole
  • Mounting Type
    Free Hanging
  • Package / Case
    Cylindrical Probe, Plastic
  • Number of Pins
    2
  • RTD Material
    Platinum
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -70°C~260°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Series
    HEL-700
  • Published
    1998
  • Tolerance
    0.2%
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Wire Leads
  • Resistance
    1kOhm
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    260°C
  • Min Operating Temperature
    -200°C
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    50MOhm
  • Interface
    2-Wire, Serial
  • Operating Supply Current
    1mA
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    2mA
  • Current
    1mA
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    305mm
  • Accuracy
    ±0.5°C
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    150 ms
  • Linearity
    2 %
  • Resistance Tolerance

    Tolerance is the percentage of error in the resistor's resistance, or how much more or less you can expect a resistor's actual measured resistance to be from its stated resistance. A gold tolerance band is 5% tolerance, silver is 10%, and no band at all would mean a 20% tolerance.

    ±0.2%
  • Resistance @ 0°C
    1kOhms
  • Length
    4.75mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Honeywell Sensing and Productivity Solutions HEL-705-U-0-12-00.