SR3F-A1

Honeywell Sensing and Productivity Solutions SR3F-A1

Part No:

SR3F-A1

Datasheet:

SR3 Series

Package:

Barrel, Plastic Housed, Flange Mount

ROHS:

AINNX NO:

7540955-SR3F-A1

Description:

SENSOR HALL CURRENT WIRE LEADS

Products specifications
  • Factory Lead Time
    25 Weeks
  • Mount
    Screw
  • Package / Case
    Barrel, Plastic Housed, Flange Mount
  • Number of Pins
    3
  • Actuator Material

    In smart material system, actuator materials have the ability to change the shape, stiffness, position, natural frequency, damping and/or other mechanical characteristics of the smart material systems in response to changes in temperature, electric field and/or magnetic field.

    Magnet, South Pole
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C TA
  • Series
    SR3
  • Published
    1998
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Wire Leads
  • Type
    Hall Effect Switch
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85°C
  • Min Operating Temperature
    -40°C
  • Voltage - Supply
    4.5V~24V
  • Frequency
    100kHz
  • Termination Style
    Wire Leads
  • Output Voltage
    400mV
  • Output Type
    Current
  • Max Output Current

    The maximum current that can be supplied to the load.

    10mA
  • Leakage Current
    10μA
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    24V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    4.5V
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    18mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    20mA
  • Min Output Voltage
    400mV
  • Sensing Method
    Hall Effect
  • Switching Current
    20mA
  • Length
    25.4mm
  • Width
    12.45mm
  • REACH SVHC
    No SVHC
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Honeywell Sensing and Productivity Solutions SR3F-A1.