LDC32900M03B-703

Murata Electronics LDC32900M03B-703

Part No:

LDC32900M03B-703

Manufacturer:

Murata Electronics

Datasheet:

-

Package:

1210 (3225 Metric)

AINNX NO:

28135396-LDC32900M03B-703

Description:

MULTI-LAY HYBRID COUPLER 1210

Products specifications
  • Factory Lead Time
    10 Weeks
  • Package / Case
    1210 (3225 Metric)
  • Supplier Device Package
    -
  • Mfr
    Murata Electronics
  • Product Status
    Not For New Designs
  • Base Product Number
    LDC32
  • Category
    Hybrid Coupler
  • Mounting
    Surface Mount
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    85 °C
  • Rohs Code
    Yes
  • Operating Frequency (Max)
    1000 MHz
  • Manufacturer Part Number
    LDC32900M03B-703
  • Insertion Loss-Max
    3.78 dB
  • Manufacturer
    Murata Manufacturing Co Ltd
  • Part Life Cycle Code
    Not Recommended
  • Ihs Manufacturer
    MURATA MANUFACTURING CO LTD
  • Risk Rank
    8.51
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40 to 85 °C
  • JESD-609 Code
    e3
  • Pbfree Code
    Yes
  • Type
    Hybrid Coupler
  • Terminal Finish
    Tin (Sn)
  • Applications
    General Purpose
  • Construction
    COMPONENT
  • Reach Compliance Code
    compliant
  • Frequency
    800MHz ~ 1GHz
  • Pin Count

    a count of all of the component leads (or pins)

    6
  • Power - Max
    3W
  • RF/Microwave Device Type
    90 DEGREE HYBRID COUPLER
  • Insertion Loss

    the loss of signal power resulting from the insertion of a device in a transmission line or optical fiber and is usually expressed in decibels (dB).

    3.3dB
  • Isolation
    20.5dB
  • Operating Frequency-Min
    800 MHz
  • VSWR-Max
    1.43
  • Input Power-Max (CW)
    34.77 dBm
  • Characteristic Impedance
    50 Ω
  • Return Loss

    In telecommunications, return loss is a measure in relative terms of the power of the signal reflected by a discontinuity in a transmission line or optical fiber.

    15dB
  • Coupler Type
    Standard
  • Coupling Factor

    Coupling Factor (CF) measures the coupling between classes excluding coupling due to inheritance. It is the ratio between the number of actually coupled pairs of classes in a scope (e.g., package) and the possible number of coupled pairs of classes. CF is primarily applicable to object-oriented systems.

    -
0 Similar Products Remaining