SCA100T-D01-6

Murata Electronics SCA100T-D01-6

Part No:

SCA100T-D01-6

Manufacturer:

Murata Electronics

Datasheet:

SCA100T Series

Package:

12-SMD Module

ROHS:

AINNX NO:

4707415-SCA100T-D01-6

Description:

Inclinometers 2-Axis Inclinometer Analog/Digital

Products specifications
  • Mount
    Surface Mount
  • Package / Case
    12-SMD Module
  • Number of Pins
    12
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    4.75V~5.25V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~125°C TA
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Series
    SCA100T
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Obsolete
  • Moisture Sensitivity Level (MSL)
    3 (168 Hours)
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    125°C
  • Min Operating Temperature
    -40°C
  • Capacitance
    20nF
  • Output Type
    Digital
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    5.25V
  • Interface
    SPI
  • Sensitivity
    4V/g
  • Axis
    X, Y
  • Measuring Range

    The measuring range is the range of measured values for a measurand in which defined, agreed, or guaranteed error limits are not exceeded. It is delimited by a lower and an upper measuring range limit that define the measuring span.

    ±30°
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Murata Electronics SCA100T-D01-6.