E2K-C25ME1

Omron Automation and Safety E2K-C25ME1

Part No:

E2K-C25ME1

Package:

Cylinder

ROHS:

AINNX NO:

9752828-E2K-C25ME1

Description:

SENSOR PROX CAP 3MM-25MM CYLIND

Products specifications
  • Factory Lead Time
    7 Weeks
  • Mount
    Brackets, Panel
  • Package / Case
    Cylinder
  • Number of Pins
    3
  • Material
    ABS
  • Housing Material
    Polycarbonate
  • Material - Body
    Plastic
  • SwitchingFrequency
    70Hz
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C~70°C
  • Series
    E2K
  • Published
    2005
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Cable Leads
  • Voltage - Supply
    10V~40V
  • Shielding
    Unshielded
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP66
  • Reach Compliance Code
    unknown
  • Termination Style
    Cable Leads
  • Output Type
    NPN-NO, 3-Wire
  • Lead Length
    2m
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    24V
  • Operating Supply Current
    15mA
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    0.118 ~ 0.984 (3mm ~ 25mm)
  • Sensor Type
    Capacitive
  • Indicator

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    LED
  • Load Current

    The Load Current can be defined as 1) Full load current the maximum current that an electrical machine can operate; 2) Rated Current the current rated on the nameplate of an electrical machine; 3) Nominal Current is generally mentioned in the specification documents that is normally the same value as the rated one.

    200mA
  • Max Supply Voltage (DC)
    40V
  • Outside Diameter

    The outer diameter (OD) of a hollow circular pipe is the measurement of the outside edges of the pipe passing through its center.

    34 mm
  • Min Supply Voltage (DC)
    10V
  • Height
    34mm
  • Length
    82mm
  • Width
    34mm
  • REACH SVHC
    No SVHC
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining