EE-SPW311

Omron Automation and Safety EE-SPW311

Part No:

EE-SPW311

Package:

-

ROHS:

AINNX NO:

5959979-EE-SPW311

Description:

OPTICAL SENSOR TRANSMISSIVE / SLOTTED INTERRUPTER

Products specifications
  • Factory Lead Time
    2 Weeks
  • Mount
    Socket
  • Number of Pins
    3
  • Housing Material
    PBT
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -10°C~55°C
  • Published
    2002
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Wire
  • Voltage - Supply
    5V~24V
  • Number of Functions
    1
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IEC IP60
  • Reach Compliance Code
    unknown
  • Output Voltage
    800mV
  • Output Type
    Phototransistor
  • Lead Length
    2m
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    24V
  • Number of Channels
    1
  • Output Configuration
    NPN - Open Collector/Dark-ON
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    100mA
  • Optoelectronic Device Type
    LOGIC OUTPUT SLOTTED SWITCH
  • Forward Current

    Current which flows upon application of forward voltage.

    20mA
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    1ms
  • Adjustment Type
    Adjustable
  • Max Collector Current
    100mA
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    39.370 (1m)
  • Sensing Method
    Through-Beam
  • Max Input Current
    40mA
  • Input Current
    40mA
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Connector
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    Infrared (940nm)
  • Touchscreen
    Infrared (IR)
  • Slot Width-Nom
    13.4mm
  • Height
    27mm
  • Length
    25.4mm
  • Width
    8mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Contains Lead
  • Ratings
    IP60