LCS7260C-TL

Power Integrations LCS7260C-TL

Part No:

LCS7260C-TL

Manufacturer:

Power Integrations

Datasheet:

-

Package:

24-PowerSMD Module (0.425, 10.80mm Width), 17 Leads

AINNX NO:

57472800-LCS7260C-TL

Description:

80 W, 600 V

Products specifications
  • Mounting Type
    Surface Mount
  • Package / Case
    24-PowerSMD Module (0.425, 10.80mm Width), 17 Leads
  • Supplier Device Package
    InSOP-24C
  • Package
    Tape & Reel (TR)
  • Mfr
    Power Integrations
  • Product Status
    Active
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 105 C
  • Minimum Operating Temperature
    - 40 C
  • Mounting Styles
    SMD/SMT
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 105°C (TA)
  • Series
    -
  • Type
    Converters
  • Power (Watts)
    80 W
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    2.9 A
  • Voltage - Supply (Vcc/Vdd)
    10.8V ~ 385V
  • Control Features
    Frequency Control, Soft Start
  • Topology
    Flyback, Secondary Side SR
  • Frequency - Switching
    90kHz, 120kHz, 180kHz, 240kHz
  • Internal Switch(s)
    Yes
  • Fault Protection

    Protection against electric shock under. single fault conditions.

    Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit, UVLO
  • Duty Cycle

    the percentage of the ratio of pulse duration, or pulse width (PW) to the total period (T) of the waveform.

    -
  • Output Isolation
    Isolated
  • Voltage - Breakdown
    600V
  • Voltage - Start Up
    13.2 V
  • Output Voltage Range

    The range of the voltage released by a device, such as a voltage regulator or a generator. Voltage regulators maintain constant voltage levels.

    5.17 V