Mounting Type
Chassis Mount
Mount
Panel
Weight
-
Mfr
Schneider Electric
Package
Box
Product Status
Active
For Use With/Related Products
-
Voltage, Rating
230 V
RoHS
Compliant
Standards Met
CE, CSA, UL
Output Frequency
400Hz
For Use With
AC Motors
Supporting protocol for PROFINET IO
No
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
No
Number of digital inputs
4
Supporting protocol for ASI
No
Number of interfaces PROFINET
0
Supporting protocol for EtherNet/IP
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Number of HW-interfaces serial TTY
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet
No
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS
No
Supporting protocol for LON
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces other
8
Number of HW-interfaces USB
0
Supporting protocol for PROFIsafe
No
Supporting protocol for KNX
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for CAN
No
Number of digital outputs
1
Number of HW-interfaces RS-485
1
Supporting protocol for MODBUS
Yes
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for TCP/IP
No
With optical interface
No
Supporting protocol for PROFIBUS
No
Factory Pack QuantityFactory Pack Quantity
1
Manufacturer
Schneider Electric
Brand
Schneider Electric
Series
Altivar
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-10°C ~ 60°C
Type
Module
Subcategory
Motors & Motor Drives
Power Rating
3 kW
Voltage - Supply
-
Supply Voltage
230 V ac
Depth
141.2
Current Rating
Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.
15.9 A
Output Voltage
230 V
Operating Supply Voltage
The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.
240 V
Interface
RS-485
Output Current
The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.
12.2 A
Current - Output
12.2A
Max Output Voltage
The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.
230 V
Product Type
a group of products which fulfill a similar need for a market segment or market as a whole.
Motor Drives
Number of Phases
3 Phase
Voltage - Load
200 ~ 240V
Max Supply Voltage (AC)
230 V
Drive Type
Variable Speed
Motor Type
AC Motor
Control / Drive Type
Variable Frequency Drive (VFD)
Number of Motors
1
Overall Length
184mm
Wattage - Load
2200 W
Features
-
Overall Depth
141mm
Product Category
a particular group of related products.
Motor Drives
Phase
3
IP Rating
IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.
IP20
Length
184 mm
Width
140
Height
184
REACH SVHC
Unknown
Ratings