PFUF.110.2

Schurter Inc. PFUF.110.2

Part No:

PFUF.110.2

Manufacturer:

Schurter Inc.

Datasheet:

-

Package:

1210 (3225 Metric), Concave

ROHS:

AINNX NO:

9818056-PFUF.110.2

Description:

Fuse;Resettable;40A;Sz 1210;Dims 3.43x2.8x0.85mm;SMT;6VDC;PCB;PFUF Series

Products specifications
  • Factory Lead Time
    12 Weeks
  • Mount
    PCB
  • Mounting Type
    Surface Mount
  • Package / Case
    1210 (3225 Metric), Concave
  • Terminal Shape
    WRAPAROUND
  • Weight
    19.986414mg
  • Terminal Material
    Electroless Nickel
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    6V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Series
    PFUF
  • Size / Dimension
    0.127Lx0.102W 3.22mmx2.58mm
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Vendor Undefined
  • Number of Terminations
    2
  • Termination
    SMD/SMT
  • ECCN Code
    EAR99
  • Type
    Polymeric
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    0.05 OHMS AT 23 DEG CEL
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8533.40.80.70
  • Voltage - Rated DC
    6V
  • Packing Method
    TR, BLISTER, 7 INCH
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    40A
  • Case Code (Metric)
    3225
  • Approval Agency
    cURus, TUV
  • Case Code (Imperial)
    1210
  • Max Current Rating
    40A
  • Power Dissipation

    the process by which an electronic or electrical device produces heat (energy loss or waste) as an undesirable derivative of its primary action.

    600mW
  • Terminal Placement
    DUAL ENDED
  • Max Voltage Rating (DC)
    6V
  • Rated (AC) Voltage (URac)
    6V
  • Hold Current

    the minimum current which must pass through a circuit in order for it to remain in the 'ON' state.

    1.1A
  • Current - Hold (Ih) (Max)
    1.1A
  • Thermistor Application
    OVERLOAD PROTECTION
  • Time to Trip
    1s
  • Resistance - Initial (Ri) (Min)
    50mOhm
  • Resistance - Post Trip (R1) (Max)
    210mOhm
  • Trip Current

    the current at which the device is guaranteed to trip.

    2.2A
  • Height
    850μm
  • Thickness (Max)
    0.028 0.70mm
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Schurter Inc. PFUF.110.2.