3RH21311BP40

Siemens 3RH21311BP40

Part No:

3RH21311BP40

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28579460-3RH21311BP40

Description:

CONTACTOR RELAY 3NO+1NC DC 230V

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Mfr
    Siemens
  • Box
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Base Product Number
    3RH21311
  • Dim
    (W x H x D) 45 x 57.5 x 73 mm
  • RoHS-compliant
    Yes
  • Number of auxiliary contacts as normally open contact
    3
  • Min. temperature
    -25°C
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Auxiliary contact type
    1 breaker,3 makers
  • Number of auxiliary contacts as normally closed contact
    1
  • Rated control supply voltage at AC 50 Hz
    0 - 0
  • Rated control supply voltage at AC 60 Hz
    0 - 0
  • Voltage type for actuating
    DC
  • Rated control supply voltage at DC
    230 - 230
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    S00
  • Depth
    73mm
  • Termination Style
    Screw Terminal
  • Interface
    No
  • Durability
    3000 0000
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-3NO/1NC (3 Form A, 1 Form B)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    100 ms
  • Coil Voltage
    230VDC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    13 ms
  • Must Operate Voltage
    184 VDC
  • Contact Rating (Current)
    10 A
  • Coil Power
    4W
  • Must Release Voltage
    -
  • Features
    Auxiliary Contacts
  • Width
    45mm
  • Height
    57.5mm
0 Similar Products Remaining