3RH22622BB40

Siemens 3RH22622BB40

Part No:

3RH22622BB40

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

29591804-3RH22622BB40

Description:

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Dim
    (W x H x D) 45 x 70 x 121 mm
  • RoHS-compliant
    Yes
  • Number of auxiliary contacts as normally open contact
    6
  • Min. temperature
    -25°C
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Auxiliary contact type
    2 breakers,6 makers
  • Number of auxiliary contacts as normally closed contact
    2
  • Range
    SIRIUS
  • Base Product Number
    3RH22622
  • Mfr
    Siemens
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    S00
  • Depth
    121mm
  • Termination Style
    Spring Terminal
  • Durability
    1000 0000
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    10 A
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    8PST-6NO/2NC (6 Form A, 2 Form B)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    100 ms
  • Coil Voltage
    24VDC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    13 ms
  • Must Operate Voltage
    19.2 VDC
  • Contact Rating (Current)
    10 A
  • Coil Power
    4W
  • Must Release Voltage
    -
  • Control Voltage
    24 Vdc
  • Features
    Auxiliary Contacts
  • Width
    45mm
  • Height
    70mm
0 Similar Products Remaining