3RT20261AV60

Siemens 3RT20261AV60

Part No:

3RT20261AV60

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28489216-3RT20261AV60

Description:

CONTACTOR S0 25A 480VAC 1NO/1NC

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Mfr
    Siemens
  • Package
    Bulk
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Base Product Number
    3RT2026
  • Dim
    (W x H x D) 45 x 85 x 97 mm
  • Connections
    Screws
  • No. of pins
    3-pin
  • Number of auxiliary contacts as normally open contact
    1
  • Nominal voltage
    690V AC
  • Number of normally open contacts as main contact
    3
  • Rated operation current Ie at AC-4, 400 V
    15.5A
  • Min. temperature
    -25°C
  • Rated operation current Ie at AC-3, 400 V
    25A
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Rated operation power at AC-3, 400 V
    11.0kW
  • Rated operation power at AC-4, 400 V
    7.5kW
  • Rated operation current Ie at AC-1, 400 V
    40A
  • Number of auxiliary contacts as normally closed contact
    1
  • Series
    3RT2
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    S0
  • Depth
    97mm
  • Termination Style
    Screw Terminal
  • Durability
    1000 0000
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    3PST-NO (3 Form A)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    40 ms
  • Coil Voltage
    480VAC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    16 ms
  • Must Operate Voltage
    408 VAC
  • Contact Rating (Current)
    25 A
  • Coil Power
    87VA
  • Must Release Voltage
    -
  • Features
    Auxiliary Contacts
  • Width
    45mm
  • Height
    85mm
0 Similar Products Remaining