DPX4024WS15

TDK-Lambda Americas Inc. DPX4024WS15

Part No:

DPX4024WS15

Datasheet:

DPX40,60 Series

Package:

Module

ROHS:

AINNX NO:

6166705-DPX4024WS15

Description:

CONV DC/DC SGL 15V 2.666A 40W

Products specifications
  • Factory Lead Time
    13 Weeks
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Package / Case
    Module
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Series
    DPX (40W)
  • Published
    2011
  • Size / Dimension
    4.92Lx0.96W x 2.27 H 125.0mmx24.5mmx57.6mm
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Type
    Enclosed
  • Applications
    ITE (Commercial)
  • Power Rating
    40W
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    40W
  • Number of Outputs
    1
  • Approval Agency
    CE
  • Efficiency
    85%
  • Voltage - Input (Max)
    36V
  • Output Voltage
    15V
  • Max Output Current

    The maximum current that can be supplied to the load.

    2.67A
  • Voltage - Input (Min)
    9.5V
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    2.67A
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    40W
  • Current - Output 1
    2.666A
  • Nominal Input Voltage

    The actual voltage at which a circuit operates can vary from the nominal voltage within a range that permits satisfactory operation of equipment. The word “nominal” means “named”.

    24V
  • Max Output Power

    The maximum output power = the maximum output current × the rated output voltage

    40W
  • Nominal Output Voltage
    15V
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    1.6kV
  • Height
    57.658mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for TDK-Lambda Americas Inc. DPX4024WS15.