NB-PTCO-167

TE Connectivity NB-PTCO-167

Part No:

NB-PTCO-167

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

2-SIP

AINNX NO:

45474449-NB-PTCO-167

Description:

Pt1000 ,2.0x5.0, Class C, PTFD102C1G0

Products specifications
  • Lifecycle Status
    Production (Last Updated: 6 days ago)
  • Factory Lead Time
    10 Weeks, 1 Day
  • Mounting Type
    Through Hole
  • Package / Case
    2-SIP
  • RTD Material
    Platinum (Pt)
  • Manufacturer Lifecycle Status
    ACTIVE (Last Updated: 6 days ago)
  • Package
    Box
  • Mfr
    TE Connectivity Measurement Specialties
  • Product Status
    Active
  • Package Description
    PACKAGE-2
  • Package Shape/Style
    RECTANGULAR
  • Operating Temperature-Min
    -50 °C
  • Operating Temperature-Max
    600 °C
  • Rohs Code
    Yes
  • Manufacturer Part Number
    NB-PTCO-167
  • Manufacturer
    TE Connectivity
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    TE CONNECTIVITY LTD
  • Risk Rank
    5.67
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -50°C ~ 600°C
  • Series
    -
  • Termination
    PC Pins
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    3850ppm/°C
  • Resistance
    1 kOhms
  • Reach Compliance Code
    unknown
  • Body Length or Diameter
    5 mm
  • Body Breadth
    2 mm
  • Termination Type
    WIRE
  • Accuracy
    -
  • Sensors/Transducers Type
    TEMPERATURE SENSOR,RTD,PLATINUM
  • Resistance Tolerance

    Tolerance is the percentage of error in the resistor's resistance, or how much more or less you can expect a resistor's actual measured resistance to be from its stated resistance. A gold tolerance band is 5% tolerance, silver is 10%, and no band at all would mean a 20% tolerance.

    -
  • Housing
    PLATINUM
  • Product
    Temperature Sensors
  • Resistance @ 0°C
    1 kOhms
  • R0-Nom
    1000 Ω
  • Body Height
    1.1 mm
0 Similar Products Remaining