7022PC

TE Connectivity Aerospace, Defense and Marine 7022PC

Part No:

7022PC

Package:

-

AINNX NO:

5351923-7022PC

Description:

TE CONNECTIVITY / AGASTAT 7022PC TIME DELAY RELAY, DPDT, 15S, 240VAC

Products specifications
  • Lifecycle Status
    ACTIVE (Last Updated: 3 days ago)
  • Factory Lead Time
    10 Weeks
  • Mount
    Panel
  • Mounting Type
    Panel Mount
  • Number of Pins
    8
  • Weight
    113.398093g
  • ElectricalLife
    100000 Cycle(s)
  • Series
    7000, AGASTAT
  • Published
    2008
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Screw
  • ECCN Code
    EAR99
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    75°C
  • Min Operating Temperature
    -30°C
  • Voltage - Supply
    125VDC
  • Depth
    82.6mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    15A
  • Reference Standard
    CE; CSA; FM; UL
  • Termination Style
    Screw Terminal
  • Function
    Off-Delay
  • Voltage - Rated AC
    20V
  • Approval Agency
    CE, CSA, UL
  • Body Breadth
    65.3 mm
  • Circuit
    DPDT (2 Form C)
  • ELV
    Non-Compliant
  • Max Voltage Rating (AC)
    240V
  • Max Current Rating
    10A
  • Throw Configuration
    DPDT
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    10A
  • Relay Type
    Mechanical Relay
  • Contact (AC) Max Rating R Load
    10A@240VAC
  • Contact (DC) Max Rating R Load
    15A@30VDC
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    8W
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Contact Rating @ Voltage
    10A @ 240VAC
  • Coil Voltage (DC)
    125V
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    1.5 Sec ~ 15 Sec
  • Timing Adjustment Method
    Hand Dial
  • Timing Initiate Method

    The initiation time (also known as release time) is the time at which the process goes from the waiting to the ready state. An aperiodic process is by definition initiated by an event, such as external data arriving or data computed by another process.

    Input Voltage
  • Nominal Input Voltage (DC)
    125V
  • Length
    82.55mm
  • Width
    82.55mm
  • Body Height
    71.9mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    Non-RoHS Compliant
  • Lead Free
    Not Applicable
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for TE Connectivity Aerospace, Defense and Marine 7022PC.