T60404N4646X101

VACUUMSCHMELZE T60404N4646X101

Part No:

T60404N4646X101

Manufacturer:

VACUUMSCHMELZE

Datasheet:

-

Package:

Module, Single Pass Through

AINNX NO:

28371446-T60404N4646X101

Description:

CURRENT SENSOR, 100A, PRI OPEN,

Products specifications
  • Mounting Type
    Through Hole
  • Package / Case
    Module, Single Pass Through
  • Mfr
    VACUUMSCHMELZE
  • Package
    Box
  • Product Status
    Active
  • Current Sensing

    Current sensing refers to the generation of the voltage signal which is related to the current passing in the circuit.

    100A
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 85 C
  • Minimum Operating Temperature
    - 40 C
  • Factory Pack QuantityFactory Pack Quantity
    120
  • Part # Aliases
    4646-X101
  • Manufacturer
    Vacuumschmelze
  • Brand
    Vacuumschmelze
  • RoHS
    Details
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 85°C (TA)
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tray
  • Subcategory
    Sensors
  • Voltage - Supply
    ±11.4V ~ 15.75V
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    100 A
  • Frequency
    DC ~ 200kHz
  • Output
    Ratiometric, Current
  • Current - Supply (Max)
    18mA
  • Output Type
    Analog - Current
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    15 V
  • Number of Channels
    1
  • Polarization
    Unidirectional
  • Core Size
    8.5 mm X 12.7 mm
  • Accuracy
    ±0.5%
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    1μs
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    Current Sensors
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    - 40 C to + 85 C
  • Sensor Type
    Closed Loop
  • Linearity
    ±0.1%
  • Frequency Range

    A continuous range or spectrum of frequencies that extends from one limiting frequency to another.

    DC to 200 kHz
  • Sensitivity
    -
  • For Measuring
    AC/DC
  • Product Category

    a particular group of related products.

    Board Mount Current Sensors
  • Width
    14.3 mm
  • Height
    27.6 mm
  • Length
    36.5 mm
0 Similar Products Remaining