HCPL-2602-500E

Broadcom Limited HCPL-2602-500E

Part No:

HCPL-2602-500E

Manufacturer:

Broadcom Limited

Package:

8-SMD, Gull Wing

ROHS:

AINNX NO:

8580213-HCPL-2602-500E

Description:

Optocoupler Logic-Out Open Collector DC-IN 1-CH 8-Pin PDIP SMD T/R

Products specifications
  • Factory Lead Time
    17 Weeks
  • Mount
    Surface Mount
  • Mounting Type
    Surface Mount
  • Package / Case
    8-SMD, Gull Wing
  • Number of Pins
    8
  • Number of Elements
    1
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Published
    2013
  • JESD-609 Code
    e3
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • ECCN Code
    EAR99
  • Type
    Line Receiver
  • Terminal Finish
    Matte Tin (Sn)
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    OPEN COLLECTOR, UL RECOGNIZED, TTL COMPATABLE
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    40mW
  • Voltage - Supply
    4.5V~5.5V
  • Supply Voltage
    5.5V
  • Approval Agency
    CSA, UR
  • Voltage - Isolation
    3750Vrms
  • Output Voltage
    5.5V
  • Max Output Current

    The maximum current that can be supplied to the load.

    50mA
  • Configuration
    COMPLEX
  • Number of Channels
    1
  • Power Dissipation

    the process by which an electronic or electrical device produces heat (energy loss or waste) as an undesirable derivative of its primary action.

    40mW
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    50mA
  • Voltage - Forward (Vf) (Typ)
    2.3V
  • Propagation Delay

    the flight time of packets over the transmission link and is limited by the speed of light.

    75 ns
  • Input Type
    AC, DC
  • Turn On Delay Time

    Turn-on delay, td(on), is the time taken to charge the input capacitance of the device before drain current conduction can start.

    75 ns
  • Forward Current

    Current which flows upon application of forward voltage.

    60mA
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    1e-7 ns
  • Data Rate

    Data Rate is defined as the amount of data transmitted during a specified time period over a network. It is the speed at which data is transferred from one device to another or between a peripheral device and the computer. It is generally measured in Mega bits per second(Mbps) or Mega bytes per second(MBps).

    10 Mbps
  • Direction
    Unidirectional
  • Output Current per Channel
    50mA
  • Rise Time

    In electronics, when describing a voltage or current step function, rise time is the time taken by a signal to change from a specified low value to a specified high value.

    24ns
  • Fall Time (Typ)
    10 ns
  • Rise / Fall Time (Typ)
    24ns 10ns
  • Reverse Breakdown Voltage
    950mV
  • Input Current
    60mA
  • On-State Current-Max
    0.05A
  • Propagation Delay tpLH / tpHL (Max)
    75ns, 75ns
  • Common Mode Transient Immunity (Min)
    1kV/μs
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Broadcom Limited HCPL-2602-500E.