3RP25052BB30

Siemens 3RP25052BB30

Part No:

3RP25052BB30

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28528456-3RP25052BB30

Description:

RELAY TIME DELAY

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Siemens
  • Package
    Box
  • Product Status
    Active
  • Base Product Number
    3RP2505
  • Dim
    (W x H x D) 22.5 x 100 x 90 mm
  • RoHS-compliant
    Yes
  • Min. temperature
    -25°C
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Electrical lifespan
    100000
  • Switch Configuration
    DP4T
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +60°C
  • Minimum Operating Temperature
    -25°C
  • PowerSupply
    External
  • Contact Materials
    Silver Tin Oxide
  • Rated control supply voltage at AC 50 Hz
    24 - 24
  • Type of electric connection
    Spring clamp connection
  • Rated control supply voltage at AC 60 Hz
    24 - 24
  • Voltage type for actuating
    AC/DC
  • Rated control supply voltage at DC
    24 - 24
  • Manufacturer Part Number
    3RP2505-2BB30
  • Manufacturer
    Siemens
  • Part Life Cycle Code
    Contact Manufacturer
  • Ihs Manufacturer
    SIEMENS A G
  • Risk Rank
    5.76
  • Series
    SIRIUS
  • Type
    3RP2505-2BB30
  • Voltage - Supply
    24VAC/DC
  • Supply Voltage
    24V ac/dc
  • Depth
    90mm
  • Reach Compliance Code
    unknown
  • Termination Style
    Spring Terminal
  • Function
    Programmable (Multi-Function)
  • Number of Contacts
    2
  • Circuit
    DPDT (2 Form C)
  • Durability
    1000 0000
  • Relay Type
    Mechanical Relay
  • Terminal Type

    Terminal type or emulation specifies how your computer and the host computer to which you are connected exchange information.

    Push In
  • Contact Rating @ Voltage
    3A @ 250VAC
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.05 Sec ~ 100 Hrs
  • Timing Adjustment Method
    Screwdriver Slot
  • Timing Initiate Method

    The initiation time (also known as release time) is the time at which the process goes from the waiting to the ready state. An aperiodic process is by definition initiated by an event, such as external data arriving or data computed by another process.

    Input Voltage
  • Contact Configuration
    DPDT
  • Mode of Operation

    There are 5 types of mode of operation, Electronic CodeBook (ECB), Cipher Block Chaining (CBC), Cipher feedback (CFB), Output Feedback (OFB), Counter Mode (CTR).

    Multifunction
  • Width
    22.5
  • Height
    100mm
  • Length
    22.5mm
0 Similar Products Remaining