3RP25251AW30

Siemens 3RP25251AW30

Part No:

3RP25251AW30

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28488966-3RP25251AW30

Description:

RELAY TIME DELAY 100HR 3A 250V

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Siemens
  • Package
    Bulk
  • Product Status
    Active
  • Base Product Number
    3RP2525
  • Dim
    (W x H x D) 17.5 x 100 x 90 mm
  • RoHS-compliant
    Yes
  • Min. temperature
    -25°C
  • Content
    1pc(s)
  • Min. operating voltage
    12V
  • Max. temperature
    +60°C
  • Electrical lifespan
    100000
  • Max. operating voltage
    240V
  • Switch Configuration
    SPDT
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +60°C
  • Minimum Operating Temperature
    -25°C
  • Contact Materials
    AgSnO2
  • Rated control supply voltage at AC 50 Hz
    12 - 240
  • Type of electric connection
    Screw connection
  • Rated control supply voltage at AC 60 Hz
    12 - 240
  • Voltage type for actuating
    AC/DC
  • Rated control supply voltage at DC
    12 - 240
  • Manufacturer Part Number
    3RP2525-1AW30
  • Manufacturer
    Siemens
  • Part Life Cycle Code
    Contact Manufacturer
  • Ihs Manufacturer
    SIEMENS A G
  • Risk Rank
    5.29
  • Series
    SIRIUS 3RP25
  • Type
    3RP2525-1AW30
  • Voltage - Supply
    12 ~ 240VAC/DC
  • Supply Voltage
    12 → 240V ac/dc
  • Depth
    90mm
  • Reach Compliance Code
    unknown
  • Termination Style
    Screw Terminal
  • Function
    On-Delay
  • Number of Contacts
    1
  • Circuit
    SPDT (1 Form C)
  • Durability
    1000 0000
  • Relay Type
    Mechanical Relay
  • Terminal Type

    Terminal type or emulation specifies how your computer and the host computer to which you are connected exchange information.

    Screw
  • Contact Rating @ Voltage
    3A @ 250VAC
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.05 Sec ~ 100 Hrs
  • Timing Adjustment Method
    Screwdriver Slot
  • Timing Initiate Method

    The initiation time (also known as release time) is the time at which the process goes from the waiting to the ready state. An aperiodic process is by definition initiated by an event, such as external data arriving or data computed by another process.

    -
  • Contact Configuration
    SPDT
  • Mode of Operation

    There are 5 types of mode of operation, Electronic CodeBook (ECB), Cipher Block Chaining (CBC), Cipher feedback (CFB), Output Feedback (OFB), Counter Mode (CTR).

    ON Delay
  • Time Delay
    250ms
  • Width
    17.5
  • Height
    100mm
  • Length
    90mm
0 Similar Products Remaining