V23230D2001B200

TE Connectivity V23230D2001B200

Part No:

V23230D2001B200

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

-

AINNX NO:

31110576-V23230D2001B200

Description:

Automotive Relays 12VDC 1FORM B IP46 HCR200 SCRW TERM

Products specifications
  • Weight
    230 g
  • Number of Terminals
    4
  • End Contact Material
    Silver Tin Oxide
  • CoilResistance
    43 Ohms
  • Mounting Styles
    Flange Mount
  • Contact Materials
    Silver Tin Oxide (AgSnO)
  • Factory Pack QuantityFactory Pack Quantity
    50
  • Part # Aliases
    1-1414995-0
  • RoHS
    Non-Compliant
  • Coil Voltage-Nom
    12 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    110 °C
  • Rohs Code
    Yes
  • Manufacturer Part Number
    V23230-D2001-B200
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    TE CONNECTIVITY LTD
  • Risk Rank
    5.56
  • Series
    V23232
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • ECCN Code
    EAR99
  • Reach Compliance Code
    unknown
  • Body Length or Diameter
    72 mm
  • Body Breadth
    35.53 mm
  • Physical Dimension
    72mm x 35.53mm x 42.5mm
  • Termination Type
    SCREW
  • Throw Configuration
    SPST
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    175 A
  • Contact Termination
    Quick Connect
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    25 ms
  • Coil Voltage
    12 VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non-Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    24 VDC
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    175 A
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    35 ms
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    3.3 W
  • Contact/Output Supply Type
    DC
  • Relay Action
    LATCHED
  • Coil/Input Supply Type
    DC
  • Dielectric Strength Between Open Contacts
    500 Vrms
  • Input Switching Control Type
    Random
  • Dielectric Strength Between Coil and Contacts
    500 Vrms
  • Relay Function
    SPST
  • Relay Form
    1 FORM B
  • Coil Operate Voltage(DC)
    7.2 V
  • Coil Release Voltage(DC)
    1.2 V
  • Coil Termination
    Screw
  • IP Rating

    IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.

    IP46
  • Length
    72 mm
  • Width
    35.35 mm
  • Height
    425.mm
  • Body Height
    42.5 mm