RT314F12

TE Connectivity Potter & Brumfield Relays RT314F12

Part No:

RT314F12

Package:

-

ROHS:

AINNX NO:

879242-RT314F12

Description:

Electromechanical Relay 12VDC 240Ohm 16A SPDT (29x12.7x15.7)mm THT Power Relay

Products specifications
  • Lifecycle Status
    ACTIVE (Last Updated: 5 days ago)
  • Factory Lead Time
    21 Weeks
  • Mount
    PCB, Through Hole
  • Mounting Type
    Through Hole
  • Number of Pins
    9
  • Weight
    14.004664g
  • CoilResistance
    240Ohm
  • Contact Materials
    Silver Nickel (AgNi)
  • ElectricalLife
    6000 Cycle(s)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Series
    RT1 Bistable, SCHRACK
  • Published
    2011
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    9
  • Termination
    Plug
  • Packing Method
    BULK
  • Depth
    12.7mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    16A
  • Reference Standard
    CSA; UL; VDE
  • Termination Style
    PC Pin
  • Approval Agency
    CSA, VDE, cULus
  • Number of Contacts
    1
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    10GOhm
  • Sealing
    RT2
  • ELV
    Compliant
  • Max Voltage Rating (AC)
    400V
  • Throw Configuration
    SPDT
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    General Purpose
  • Dropout Voltage

    Dropout voltage is the input-to-output differential voltage at which the circuit ceases to regulate against further reductions in input voltage; this point occurs when the input voltage approaches the output voltage.

    8.4V
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    10ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Latching, Dual Coil
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    400VAC -Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    50mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    7 ms
  • Must Operate Voltage
    8.4VDC
  • Coil Power
    600mW
  • Contact/Output Supply Type
    AC
  • Relay Action
    LATCHED
  • Coil Voltage (DC)
    12V
  • Coil/Input Supply Type
    DC
  • PCB Hole Count
    9
  • Seal Rating
    Sealed - Flux Protection
  • Input Switching Control Type
    Random
  • Coil Insulation
    Class F
  • Dielectric Strength Between Coil and Contacts
    5000 Vrms
  • Ambient Temperature Range High

    This varies from person to person, but it is somewhere between 68 and 77 degrees F on average. The temperature setting that is comfortable for an individual may fluctuate with humidity and outside temperature as well. The temperature of an air conditioned room can also be considered ambient temperature.

    85°C
  • Contact (AC) Max Power Rating R Load
    4000VA@400VAC
  • Switching Current
    16A
  • Contact Voltage Rating (AC)
    250V
  • Switching Capacity
    4 kW
  • Height
    15.7mm
  • Length
    29mm
  • Width
    12.7mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
  • Ratings
    IP54
0 Similar Products Remaining