T92S11D12-24

TE Connectivity Potter & Brumfield Relays T92S11D12-24

Part No:

T92S11D12-24

Package:

-

ROHS:

AINNX NO:

879471-T92S11D12-24

Description:

TE CONNECTIVITY / POTTER & BRUMFIELD 9-1393211-0 RELAY, POWER, PCB, 24VDC, 30A

Products specifications
  • Lifecycle Status
    ACTIVE (Last Updated: 5 days ago)
  • Factory Lead Time
    20 Weeks
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Number of Pins
    8
  • CoilResistance
    350Ohms
  • Coil Voltage AC
    24V
  • Contact Materials
    Silver Cadmium Oxide (AgCdO)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Series
    T92
  • Published
    2011
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Termination
    PC Pin
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85°C
  • Min Operating Temperature
    -55°C
  • Voltage - Rated DC
    24V
  • Depth
    34.54mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    30A
  • Termination Style
    PC Pin
  • Voltage - Rated AC
    600V
  • Number of Contacts
    2
  • ELV
    Non-Compliant
  • Max Voltage Rating (AC)
    600V
  • Throw Configuration
    DPDT
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    15ms
  • Coil Voltage
    24VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    277VAC - Nom
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    70.8mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    15ms
  • Must Operate Voltage
    18VDC
  • Contact Rating (Current)
    30A
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    1.7W
  • Coil Power
    1.7W
  • Must Release Voltage
    2.4VDC
  • Coil Voltage (DC)
    24V
  • Seal Rating
    Sealed - Fully
  • Coil Insulation
    Class F
  • Ambient Temperature Range High

    This varies from person to person, but it is somewhere between 68 and 77 degrees F on average. The temperature setting that is comfortable for an individual may fluctuate with humidity and outside temperature as well. The temperature of an air conditioned room can also be considered ambient temperature.

    85°C
  • Switching Current
    40A
  • Height
    30.73mm
  • Length
    52.3mm
  • Width
    34.5mm
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free