BTS3408GXUMA2

Infineon Technologies BTS3408GXUMA2

Part No:

BTS3408GXUMA2

Datasheet:

BTS3408G

Package:

8-SOIC (0.154, 3.90mm Width)

ROHS:

AINNX NO:

7592872-BTS3408GXUMA2

Description:

Power Switch Lo Side 0.55A Automotive 8-Pin DSO

Products specifications
  • Factory Lead Time
    18 Weeks
  • Mount
    Surface Mount
  • Mounting Type
    Surface Mount
  • Package / Case
    8-SOIC (0.154, 3.90mm Width)
  • Number of Pins
    8
  • Turn Off Delay Time

    It is the time from when Vgs drops below 90% of the gate drive voltage to when the drain current drops below 90% of the load current. It is the delay before current starts to transition in the load, and depends on Rg. Ciss.

    8 μs
  • Usage Level
    Automotive grade
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~150°C TJ
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Series
    HITFET®
  • Published
    2002
  • JESD-609 Code
    e3
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    3 (168 Hours)
  • Number of Terminations
    8
  • ECCN Code
    EAR99
  • Resistance
    1Ohm
  • Terminal Finish
    Matte Tin (Sn)
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    880mW
  • Terminal Position
    DUAL
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    GULL WING
  • Peak Reflow Temperature (Cel)
    260
  • Number of Functions
    1
  • Supply Voltage
    5V
  • Time@Peak Reflow Temperature-Max (s)
    40
  • Base Part Number
    BTS3408
  • Pin Count

    a count of all of the component leads (or pins)

    8
  • Number of Outputs
    2
  • Qualification Status

    An indicator of formal certification of qualifications.

    Not Qualified
  • Output Voltage
    60V
  • Output Type
    N-Channel
  • Max Output Current

    The maximum current that can be supplied to the load.

    1A
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    60V
  • Voltage
    60V
  • Interface
    Parallel
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    1.5mA
  • Current
    550mA
  • Output Configuration
    Low Side
  • Power Dissipation

    the process by which an electronic or electrical device produces heat (energy loss or waste) as an undesirable derivative of its primary action.

    880mW
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    550mA
  • Max Supply Current
    1.5mA
  • Input Type
    Non-Inverting
  • Turn On Delay Time

    Turn-on delay, td(on), is the time taken to charge the input capacitance of the device before drain current conduction can start.

    8 μs
  • Switch Type

    Based on their characteristics, there are basically three types of switches: Linear switches, tactile switches and clicky switches.

    General Purpose
  • Halogen Free
    Halogen Free
  • Drain to Source Voltage (Vdss)
    60V
  • Nominal Input Voltage

    The actual voltage at which a circuit operates can vary from the nominal voltage within a range that permits satisfactory operation of equipment. The word “nominal” means “named”.

    60V
  • Ratio - Input:Output
    1:1
  • Voltage - Load
    60V Max
  • Max Dual Supply Voltage

    A Dual power supply is a regular direct current power supply. It can provide a positive as well as negative voltage. It ensures stable power supply to the device as well as it helps to prevent system damage.

    60V
  • Driver Number of Bits
    2
  • Fault Protection

    Protection against electric shock under. single fault conditions.

    Current Limiting (Fixed), Open Load Detect, Over Temperature, Over Voltage
  • Screening Level
    AEC-Q100
  • Output Peak Current Limit-Nom
    0.55A
  • Rds On (Typ)
    480m Ω
  • Built-in Protections
    TRANSIENT; OVER CURRENT; OVER VOLTAGE; THERMAL
  • Features
    Auto Restart, Status Flag
  • Height
    1.45mm
  • Length
    5mm
  • Width
    4mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Infineon Technologies BTS3408GXUMA2.